Choosing the Right Vortex Tube – Max Refrigeration vs. Max Cold Temperature


The Vortex Tube is a low cost, reliable, maintenance free way to provide cooling to a wide variety of industrial spot cooling problems.
There are two (2) popular uses for the Vortex Tubes. One is to spot cool a warm item as fast as possible. The other is to chill an item to as low a temperature as possible. Because these are very different requirements, different Vortex Tube configurations exist to handle each.
For those applications of spot cooling, we recommend the 3200 series of Vortex Tubes. They are designed to be most efficient at providing maximum refrigeration, which is a function of high cold air flow rate and moderate temperature differential of the cold air to the warm item.
And for those applications of chilling an item to a very low temperature at low flow rate , we recommend the 3400 series of Vortex Tubes. They are designed to be most efficient at providing maximum cold air temperatures, but with a lower cold air flow rate.
An important parameter for the Vortex Tubes is the Cold Fraction. By adjusting the hot valve on a vortex tube, the amount of air that is discharged through the cold end changes. When expressed as a percentage of the total compressed air that is supplied to the vortex tube, we get the Cold Fraction. For example, if the hot valve is adjusted so that for every 10 parts of compressed air supplied, we get 7 parts of cold air, then we have a 70% Cold Fraction. When you know the Cold fraction setting and the compressed air supply pressure, you can use the Vortex Tube Performance tables and get the cold air discharge temperature.
Using the table below left, at 100 PSIG compressed air pressure and a 70% Cold Fraction, we can expect the cold air discharge temperature drop to be 71°F. With 70 ° compressed air temperature, the cold air will be at -1°F.



The 3200 series of Vortex Tubes are for use in the 50-80% Cold Fraction range, and the model 3400 series is designed for use in the 20-50% Cold Fraction ranges, to maximize the performance of each.
In summary, the selection of the Vortex Tube that best meets the application needs is based on the desired cold air flow rate, and the temperature of air desired. Once these are known, using the tables can provide the information needed to select the best option.
For those applications where we are unsure what will work best, we offer the EXAIR Cooling Kits, that include a Vortex Tube (small, medium, or large) and an array of Generators, to allow the configuration of the full range of Vortex Tubes within each size family.
  • Model 3908 – Small Vortex Tube Cooling Kit – build models 3202, 3204, 3208, and 3402, 3404, 3408
  • Model 3930 – Medium Vortex Tube Cooling Kit – build models 3210, 3215, 3225, 3230, 3240, and 3410, 3415, 3425, 3430, 3440
  • Model 3998 – Large Vortex Tube Cooling Kit – build models 3250, 3275, 3298, 3299, and models 3450, 3475, 3498, 3499