Friday, 25 February 2022

Custom Vortex Tubes by EXAIR

 EXAIR’s Vortex Tubes are a low-cost, reliable, and maintenance-free solution to a variety of industrial spot cooling problems. With just an ordinary supply of compressed air, the Vortex Tube produces two streams of air: one hot and one cold. This is achieved without any moving parts or refrigerants!!


The Vortex Tube is capable of achieving a temperature drop/rise from your compressed air supply ranging from -50°F to +260°F (-46°C to +127°C). Flow rates range from 1-150 SCFM (28-4,248 SLPM) and refrigeration of up to 10,200 Btu/hr. With all Vortex Tubes constructed of stainless steel, they’re resistant to corrosion and oxidation ensuring you years of reliable, maintenance-free operation.


In addition to providing a range of different Vortex Tubes available to ship same-day from stock, EXAIR also has a few options available for cases where a stock Vortex Tube may not be the right solution. The standard Vortex Tube is suitable for use in environments with ambient temperatures up to 125°F (52°C) due to the plastic generator and Buna o-rings. For more extreme environments and ambient temperatures up to 200°F (93°C), we install a brass generator and replace the Buna o-rings with Viton seals.

All standard Vortex Tubes are adjustable. A small valve is located at the hot air exhaust end of the tube. Using a flat-tipped screwdriver, you can adjust the amount of air that is permitted to exhaust from the hot end. As more air is allowed to escape, the temperature at the cold end of the tube drops even further. The volume of air at the cold end as the temperature drops will also decrease. The percentage of air exhausting from the cold end relative to the total air consumption is referred to as the cold fraction percentage. Lower cold fractions will produce lower temperatures, but there won’t be as much volume. Finding the proper setting for your Vortex Tube can take some adjusting.

As we all know, if there’s a knob to turn, button to press, or adjustment that can be made an operator is inevitably going to tinker with it. Day shift will blame the night shift, night shift blames the day shift, and it can present a problem when the Vortex Tube has been specifically tested and set to achieve the desired cold fraction. If you know the cold fraction you need, but would prefer to prevent it from being able to be adjusted, EXAIR can install a precisely drilled hot plug to set the cold fraction percentage to your specifications and eliminate any potential for it to be changed.

If you’d still prefer to keep the adjustability, but don’t have the capabilities to measure and set it yourself, we can also set any Vortex Tube to the desired cold fraction with the adjustable valve and send it to you ready to be installed. We’ll provide you with a special model number so you can rest assured that any time you need another it’ll come set to your specification.
If you have a unique application and would like more information on getting a special Vortex Tube, contact an Application Engineer today.

Vivek Engineers
#22, 1st Floor, 1st Cross, Adj. to IIMB Compound, Bilekahalli Indl. Area, 
Bannerghatta Road, Bangalore - 560 076 
Ph : 080 -  2648 1309, 4170 1145.
Mob : 097404 39220