Saturday 15 December 2018

NEW From EXAIR! The Hazardous Location Cabinet Cooler – For Use In Classified Areas

EXAIR is always focused on releasing new products and improving on existing product lines, and 2018 has been no different! Earlier on this year we introduced the New Super Air Scraper as an accessory to our 2” Flat Nozzles and Safety Air Guns. Just last month, EXAIR has also introduced a new line of products to the Cabinet Cooler family: The Hazardous Location Cabinet Cooler.
Cabinet Cooler Overview>>

EXAIR’s Hazardous Location Cabinet Coolers are engineered for use with purged (not included) electrical enclosures. The HazLoc Cabinet Coolers are not purged and pressurized control systems and should not be relied upon nor used in place of a purged and pressurized controller. They are meant for use in conjunction with a purged and pressurized control system. These systems have been approved and tested by UL for use in the following areas:
Class I Div 1&2 – Groups A, B, C, and D
Class I Areas refer to the presence of flammable gases or vapors in quantities sufficient to produce explosive or ignitable mixtures. Class I Div 1 will have ignitable concentrations of flammable gases present during the course of normal operations. This is level of approval is one that differentiates the EXAIR Hazardous Location Cabinet Coolers from much of the competition. Class 1 Div 2 areas will have flammable gasses or vapors present only in the event of an accident or during unusual operating conditions.Class II Div 1&2 – Groups E, F, and G
Class II areas are locations in which combustible dust may exist. The end user shall avoid installation of the device in a Class II environment where dust may be readily disturbed from the exhausts of the Hazardous Location Cabinet Cooler. Any dust formed in the vicinity of the cooler must be cleaned regularly.Class III
Class III areas are locations that will have ignitable fibers or flyings present. This is common within the textile industry.The Cabinet Cooler also carries a temperature rating of T3C, meaning it cannot be installed near any materials that could auto-ignite at temperatures in excess of 320°F. For a comprehensive list and description of all of the various Classified areas, check out the UL website.
The Hazardous Location Cabinet Cooler is available in (8) different cooling capacities ranging from 1,000 Btu/hr – 5,600 Btu/hr. The Cabinet Cooler is the best solution for protecting your sensitive electronics from heat, dirt, and moisture. With Nema 4/4X systems available, the Hazardous Location Cabinet Coolers will keep the cabinet cool without compromising the integrity of the enclosure.
If you’ve got an electrical cabinet installed within a hazardous location, fill out the Cabinet Cooler Sizing Guide and allow an Vivek Engineers Application Engineer to determine the most suitable model for you.
Vivek Engineers#22, 1st Floor, 1st Cross, Adj. to IIMB Compound, Bilekahalli Indl. Area, 
Bannerghatta Road, Bangalore - 560 076.
Ph : 080 -  2648 1309, 4170 1145  Mob : 097404 39220
E- mail :p.lochan@vivekengineers.net sales@vivekengineers.net , 
durga@vivekengineers.net

No comments:

Post a Comment